Application:
Used for house connections. This cable can only be used for single phase supply. Cable is made to be suspended in the air. Cable is available as a Combined Neutral and Earth (CNE) and Separate Neutral and Earth (SNE) with coms wire available in Separate Neutral and Earth (SNE).
Property:
1.Separate Neutral and Earth (SNE) Airdac 600/1000V
2.Combined Neutral and Earth (CNE) Airdac 600/1000V
Specification:
Electrical Information
Cable Size (mm²) | 10 | 16 |
Phase Conductor Resistance (Ohm/km) DC @ 20°C | 1,90 | 1,90 |
Earth Size (mm²) | 7,5 | 10 |
Neutral Size (mm3) | 10 | 16 |
Phase Core Impedance (Z) (Ohm/km) | 2,34 | 1,47 |
Current Rating* (A) | 50 | 70 |
Pilot Cores (No. x OD) Solid (mm) | 2 x 1,13 | 2 x 1,13 |
In air, with 30°C ambient with maximum conductor temperature 90°C |
Mechanical Information
Cable Size (mm²) | 10 | 16 |
Phase Conductor (No. x OD)(mm) | 7 x 1,35 | 7 x 1,67 |
Nominal Insulation Thickness (mm) | 1,0 | 1,0 |
Neutral Conductor (No. x OD)(mm) | 7 x 1,33 | 7 x 1,76 |
Earth Conductor (No. x OD)(mm) | 3 x 1,78 | 3 x 2,20 |
Nominal Sheath Thickness (mm) | 1,6 | 1,6 |
Approximate Cable OD (mm) | 12,8 | 14,5 |
Approximate Cable Mass (kg/km) | 320 | 4 |