RIF Dry-Capacitance GIS Outlet Bushing

Description:

It is unnecessary to adopt special monitoring and maintenance for the products as they belong to the gas-free and pure-soild major insulation structure products;

The partial discharge starting voltage has been improved greatly, to be free from partial discharge in operation, due to the large insulation design margin and semiconducting materials as the capacitor screen;

Inflaming retarding insulating materials with stable electrical performance and without decomposition, without combustion and explosion hazard;

Compact structure small volume, light weight, convenient for transportation, may be installed at any angle;

The products are especially suitable for the heavy earthquake regions for their reinforced fiberglass winding, optimized dynamic laying design, high bending strength and excellent mechanical performance;

Perfect high and low temperature resistant performance, ranging from +135℃, to-200°C;

The products with silicon rubber compound shell may be sued to the heavy polluted area for their excellent anti-fouling property;

Long performance life and low longtime running cost;

Products period is short; the products may be designed specially according to the use`s requirements.


Main   Performance

Technical standards

GB/T 4109-2008 IEC60137 Ed.6.0

Rated voltage

72.5KV

Rated current

630-5000A

lmin power frequency dry voltage   withstand

155KV

Full-wave impulse withstand voltage of lightning

325KV

Under 1.05 times of maximum phase voltage tanδ

≤0.004

Partial discharge under 1.5Um/√3

≤10pC

Bending resistant test load

2000N

Minimum nominal creepage distance

31mm/kv


Main   Performance

Technical standards

GB/T 4109-2008 IEC60137 Ed.6.0

Rated voltage

126KV

Rated current

630-5000A

lmin power frequency dry voltage   withstand

255KV

Full-wave impulse withstand voltage   of lightning

550KV

Under 1.05 times of maximum phase   voltage tanδ

≤0 .004

Partial discharge under 1.5Um/√3

≤10pC

Bending resistant test load

3150N

Minimum nominal creepage distance

31mm/kv


Main   Performance

Technical standards

GB/T 4109-2008 IEC60137 Ed.6.0

Rated voltage

252KV

Rated current

630-5000A

lmin power frequency dry voltage   withstand

550KV

Full-wave impulse withstand voltage   of lightning

1050KV

Operation impulse withstand voltage

850KV

Under 1.05 times of maximum phase   voltage tanδ

≤0 .004

Partial discharge under 1.5Um/√3

≤10pC

Bending resistant test load

4000N

Minimum nominal creepage distance

31mm/kv


Main   Performance

Technical standards

GB/T 4109-2008 IEC60137 Ed.6.0

Rated voltage

363KV

Rated current

630-5000A

lmin power frequency dry voltage   withstand

595KV

Full-wave impulse withstand voltage   of lightning

1175KV

Operation impulse withstand voltage

950KV

Under 1.05 times of maximum phase   voltage tanδ

≤0 .004

Partial discharge under 1.5Um/√3

≤10pC

Bending resistant test load

4000N

Minimum nominal creepage distance

31mm/kv